A 197-bedroom hotel with a leisure centre, a conference suite, and a full kitchen doesn't have the option of switching off for the night. It's exactly the kind of building that gets punished by rising energy costs - and exactly the kind of building where decarbonisation now pays for itself faster than most owners assume.

That's the shift happening across the Irish hotel sector right now. Decarbonisation used to be framed as a sustainability nice-to-have or a compliance obligation. In 2026, it's a cost-control strategy, and the numbers explain why.

The real driver: energy costs, not compliance

Commercial electricity rates in Ireland currently sit at roughly 24.5-29.5c per kWh during the day and 15-19c per kWh overnight, depending on contract and meter type. Around half of that final price is made up of regulated network, PSO levy, and tax charges layered on top of the wholesale rate - costs that don't move even when wholesale prices ease. Albeit the carbon tax on non-electricity fuels (gas, oil, coal) decreased to €48.50 in the latest Budget 2027 revision, it is legislated to climb to €100 per tonne by 2030, adding a predictable, compounding cost to any hotel still running gas boilers.

For an operator running on hospitality-sector margins that are already being squeezed by wage inflation and pension auto-enrolment costs, an exposed energy bill isn't a sustainability risk - it's a margin risk. That's the commercial logic pushing decarbonisation up the agenda, ahead of any compliance deadline.

 

Where regulation actually fits in

Regulation matters, but it's trailing the cost argument, not leading it. Ireland's Building Energy Rating system changed materially on 24 May 2026, moving from the old 15-band scale (A1 down to G) to a simplified eight-band A0-G scale under the transposed EU Energy Performance of Buildings Directive. Hotels are named specifically in the new schedule of primary energy thresholds, alongside offices and schools, with a distinct "ZEB Renovate" standard for existing buildings.

The practical effect: BER certificates issued from now on carry more detail, and a hotel's rating becomes far more visible to lenders, buyers, and corporate procurement teams doing due diligence. A poor BER doesn't yet force a retrofit - but it increasingly affects financing terms, valuation, and lease negotiations. That's a slower-burning pressure than the electricity bill, but it's real, and it's compounding in the same direction.

Guest expectations: real but secondary

Sustainability credentials do influence bookings. Major OTAs now flag environmental performance to travellers, and corporate travel policies increasingly screen suppliers on carbon reporting. Fáilte Ireland's Climate Action Programme data shows participating hotels achieving average Scope 1 and 2 emissions of around 6kg CO2e per guest night, against a sector average closer to 21kg - a meaningful gap that's starting to show up in corporate RFPs.

But guest expectations are an amplifier, not the primary driver. Almost no hotel is retrofitting its HVAC purely because guests asked. They're retrofitting because the energy bill is unsustainable, and the sustainability credentials are a welcome by-product.

 

Where the retrofit money actually goes

Not all M&E spend delivers the same payback. For most Irish hotels, the priority order looks like this:

  • Gas boiler replacement with air source heat pumps or hybrid VRF systems - the single biggest lever for hotels still on natural gas heating. These systems handle both heating and cooling, sidestep the rising carbon tax entirely, and qualify for green financing and SEAI grant support.
  • Kitchen extract and heat recovery - commercial kitchens run some of the least efficient plant in the building; recovering waste heat from extract systems is a comparatively low-disruption win.
  • Laundry heat recovery - for hotels with in-house laundry, heat recovery from wastewater and dryer exhaust can meaningfully cut one of the largest continuous energy loads on site.
  • Building Management System (BMS) upgrades and controls - often the cheapest intervention with the fastest payback, because it stops the building wasting energy it's already generating, before any capital plant is replaced.
  • The order matters. Controls and BMS optimisation should typically come first - it's low capital, low disruption, and it establishes an accurate baseline for everything that follows. Plant replacement (heat pumps, VRF) is the higher-capital, higher-impact move that follows once that baseline is understood.

 

Proof of capability: EDC and Dalata Hotel Group

This isn't theoretical. EDC recently completed a decarbonisation report for Clayton Hotel, Lapps Quay in Cork - a 197-bedroom Dalata Hotel Group property with a leisure complex, conference suite, and dining facilities, and a hotel that, like much of the Irish hotel stock, relies on natural gas boilers.

EDC's approach combined M&E visual surveys of the existing plant with a desktop feasibility study using dynamic simulation modelling, testing options from building fabric upgrades through to full M&E system replacement. The team worked with the hotel's Energy Efficient Design Expert to set an accurate energy baseline, then modelled a hybrid VRF and air source heat pump solution as the low-carbon alternative to the existing gas boilers - sized and tested against live occupancy profiles so the hotel's day-to-day operations weren't disrupted during design.

The output wasn't just a spec for new plant. It was a Part L- and NZEB-aligned strategy that gives Dalata a template that can realistically be assessed across other properties in its portfolio - which is the real value of doing this properly the first time.

 

The realistic first step

Owners and operators don't need to commit to a full plant replacement to get started, and jumping straight to procurement is where most retrofit budgets go wrong. The realistic first step is a decarbonisation feasibility report: an M&E survey of existing systems, a baseline energy model, and a comparison of low- and zero-carbon options against your actual occupancy data - before any capital is committed.

Done properly, that report tells you three things: where your energy is actually going, which interventions pay back fastest, and what sequence minimises disruption to a live, trading hotel. It's the difference between a retrofit that's guesswork and one that's engineered.

AUTHOR
Robert Higgins
Executive Director - Growth

With two decades of engineering experience, Robert began his career as a qualified electrician and progressed to attain a B-Eng in Electrical Engineering and a Masters in International Business. The last 15 Years with EDC has seen him progress to the level of Executive Director where in addition to Project Management he leads the Group Sales and Business Development Initiatives.

Robert has extensive experience managing large-scale residential projects, where he has forged successful collaborations with developers, main contractors, and MEP contractors. His skillset is marked by a unique fusion of practical technical expertise, academic achievements, and seasoned leadership skills, notably his unwavering commitment to a customer-first ethos. This distinctive combination positions him as an indispensable asset across a diverse range of sectors with particular strengths in the residential, industrial, and commercial areas.

In addition to his expertise in electrical and mechanical engineering services, Robert excels in project management and coordination within engineering and design teams. This dual expertise ensures the efficient and timely completion of projects and also underscores his pivotal role in driving sales and fostering business development initiatives at EDC.

Robert Higgins